BENDIX GEN 4 GEN 5 ABS Manual do Operador Página 73

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 112
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 72
Using EC-17, EC-30 & EC-30T Diagnostic Options
NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications 67
2 Register the ECU (see Register ECU via menu navigation:, on
page 28).
3 Brake-Link presents the
EC-17/30/30T Diagnostic
Options
menu;
scroll to
CONFIGURATION
with and keys and press
.
4 Brake-Link presents
Configuring Options
; use the and
keys to select
SELF CONFIG
and press .
5 Brake-Link prompts you for confirmation; use the and
keys to select
YES
and press .
6 Brake-Link displays a countdown while it configures the ECU; then it
returns to the
Configuration Option
menu.
7 Press to return to the
Bendix
®
ABS Application
main menu or
to return to the
Select Application
screen.
To run Self-Configuration
via button navigation
:
1 Connect Brake-Link to the tractor or trailer and power-up (see Con-
necting Brake-Link Components, on page 20).
2 Register the ECU (see Register ECU via menu navigation:, on
page 28).
3 Brake-Link instructs you to CONTINUE BY PRESSING BUTTONS;
press .
4 Next, it presents the
ECU Options
menu; use the and keys
to select
SELF-CONFIGURATION
and press .
5 Brake-Link prompts you for confirmation; use the and
keys to select
YES
and press .
6 It displays a countdown while it configures the ECU; then it returns to
the
ECU Options
menu.
7 Press to return to the CONTINUE BY PRESSING BUTTONS
prompt
or to return to the
Select Application
screen.