BENDIX SD-03-3617 Manual do Utilizador Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 7
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
4
AUTOMATIC
In the event of trailer breakaway or a sudden complete
failure of the trailer supply line, the button of the PP-7
valve will pop out when air pressure in the supply line falls
below 40 P.S.I.
OPERATION - AUTOMATIC EXHAUST (NO OVER
RIDE)
If the driver holds the button of the PP-7
valve in after
supply air pressure has dropped below the 40 P.S.I.
automatic pop out pressure, the control piston will move
into the exhaust position when control port pressure falls
below 20 P.S.I.
OPERATION - PARK APPLICATION
During a parking brake application, the park control valve
removes air pressure from the control port of the PP-7
valve. The button of the PP-7
valve remains in.
With air pressure removed from the control port of the
PP-7
valve, the control piston moves away from the
control inlet and exhaust valve. The inlet valve seats and
the exhaust passage through the control piston is open.
Air at the delivery port of the PP-7
valve is exhausted at
the exhaust port of the PP-7
valve.
FIGURE 6 - PP-7
TRAILER SUPPLY VALVE MANUAL EMERGENCY
FIGURE 7 - PP-7
TRAILER SUPPLY VALVE PARK APPLICATION
#1 Service
Reservoir
#2 Service
Reservoir
Double
Check
Valve
Park
Control
Valve
To
Parking
Brakes
Supply
Port
Plunger
Inlet & Exhaust
Exhaust Vent
Control Inlet
and Exhaust
Exhaust
Port
Control
Piston
PP-7
VALVE MANUAL EMERGENCY
PP-7
VALVE PARK APPLICATION
To Tractor
Protection
Control Port
#1 Service
Reservoir
#2 Service
Reservoir
Double
Check
Valve
Park
Control
Valve
To
Parking
Brakes
Supply
Port
Plunger
Inlet & Exhaust
Exhaust Vent
Control Inlet
and Exhaust
Exhaust
Port
Control
Piston
To Tractor
Protection
Control Port
Vista de página 3