Symptom Isolation Procedures
Side Sensor
Detection Test
3-5
Side Sensor Not Detecting Targets
Overview
This symptom driven test is performed when the system fails to
detect objects properly.
Detection
The symptom is observed by the driver when objects at three (3)
to ten (10) feet are not detected. The yellow light also continuously
illuminates when the sensor has failed.
Fallback
There is no fallback mode for this symptom. The Sensor will not
operate properly.
Required Tools
None
Possible Causes
This fault code can be caused by any of the following:
Sensor
Operator Display Unit
Harness
P2 SOD
Operator
Display Unit
(ODU)
Sensor