Relay Emergency Valves
Midland
KN30010X
4 Port Delivery
Used on converter dollies and pre-1975
trailers. Relay function applies & releases
service brakes during normal operation.
Automatically applies all service brakes
when trailer supply (emergency) line loses
pressure (disconnected or break away).
Midland/Wagner
KN30100X, KN30200X,
KN30300X, KN30400X
4 Port Delivery
Used on converter dollies and pre-1975 trail-
ers. Relay function applies & releases ser-
vice brakes during normal operation. Auto-
matically applies all service brakes when
trailer supply (emergency) line loses pres-
sure (disconnected or break away).
KN30100X
Shown
Part No.
Reservoir
Ports
Aux.
Reservoir
Delivery
Ports
Service
Ports
Emerg.
Ports
Crack
Pressure
Wght.
Core
Class
Core
Grp.
Minor
Maint. Kit
KN30010X 1 - 3/4" PT 1 - 1/4" PT 4 - 1/4" PT 1 - 1/4" PT 1 - 1/4" PT N/A 5 lbs. VW X4 VK1015M
Part No. Reservoir Ports
Aux.
Reservoir
Delivery
Ports
Service
Ports
Emerg.
Ports
Crack
Pressure
Wght.
Core
Class
Core
Grp.
Minor
Maint. Kit
KN30100X -- -- 4 - 1/4" PT 1 - 1/4" PT 1 - 1/4" PT 4.5 ±1PSI 3 lbs. VV X3 VK1022W
KN30200X 1 - 3/4" Nipple 1 - 3/8" PT 4 - 3/8" PT 1 - 3/8" PT 1 - 3/8" PT 4.5 ±1PSI 3 lbs. VV X3 VK1022W
KN30300X 1 - 3/4" Nipple -- 4 - 1/4" PT 1 - 1/4" PT 1 - 1/4" PT 4.5 ±1PSI 3 lbs. VV X3 VK1022W
KN30400X
1 - 3/4" Female
-- 4-3/8
"
PT 1-1/4
"
PT 1-1/4
"
PT 4 5 ±1PSI 3lbs VV X3 VK1022W
Delivery
Reservoir
Aux.
ReservoirEmergency
Service
Service
Delivery
Emergency
Reservoir
Aux.
Reservoir
Vista de página 21