TIPS
1. All troubleshooting should begin by performing the
“STARTUP,” which focuses on observing the antilock
status light on the dash.
2. The troubleshooting technician should record all findings
and the action taken during the troubleshooting process.
3. No voltage or resistance tests are performed into the
EC-11
controller. All electrical tests begin at the
wire-harness end of the connector and move AWAY from
the EC-11
controller toward and antilock system
component (modulator, wheel speed sensor, etc.).