FollowingDistanceSettings
The Following Distance/alerts configuration number is a numeric value that represents the current
configuration of the ACB sensor following distance setting and alerts.
ControlButtonsforConguration
TheModifybuttonwillopenthechangewindow,allowingthetechniciantoresetthealignmentvaluetozero
andchangethealertfollowingdistanceconfigurationnumber.Additionally,thetechnicianispermittedto
saveorloadtheACBsensorconfigurationfile.
TheHelpbuttonwillopentheHELPpage
TheClosebuttonwillclosethewindow
Figure41
ControlButtonsforChangeConguration
• The Write button writes the configuration changes to the ACB sensor
• The Save File button saves the configuration file of the ACB sensor
• The Load File button loads the configuration file of the ACB sensor
• The Help button will open the HELP page
• The Close button will close the window