EC-30T SIDs & FMIs
NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications 95
EC-30T SIDs & FMIs
The following tables list all EC30T Sub-system IDs (SIDs) and Failure Mode
IDs (FMIs) with complete descriptions.
Sensors
SIDs Description FMIs Description
01 Left Front Sensor 01 Needs adjustment; output low
during startup
02 Right Front Sen-
sor
02 Intermittent output; check sen-
sor adjustment and exciter ring
03 Left Rear Sensor 03 Shorted to VBAT
04 Right Rear Sensor 04 Shorted to ground
05 Open
06 Shorted across sensor
07 Output low or missing; sensor
locked out to eliminate exces-
sive modulator cycling
08 Output incorrect at speed (8)
09 Connection has corrosion; sen-
sor loose in block, output noisy.
0A Sensor or exciter ring needs
adjustment, output intermit-
tent, wobble run in exciter ring
0C Abnormal speed
0D Invalid tire size; gross mis-
match
Modulators
SIDs Description FMIs Description
07 Modulator 2 05 Open
08 Modulator 1 06 Shorted to ground
07 Not responding; sensor out of
adjustment or modulator issue
08 Shorted between
0E Solenoid shorted
Comentários a estes Manuais