Selecting a Protocol & Registering the ECU
NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications 19
2 Plug the Data Cable Atari End into the Atari End on the cable you attach
to the vehicle, i.e., Deutsch adapter or J560 PLC Cable Set.
3 Attach the vehicle interface cable to the vehicle.
If youre using the J560 PLC Cable Set, plug into the Power Line
Connector on the outside of the tractor or trailer.
If youre using the Deutsch Adapter, plug into the Deutsch Connector
typically located under the dash on the drivers side, beside the driv-
ers seat or near the brake ECU on the trailer.
Note:
Not all trailers are equipped with Deutsch Connectors.
4 If youre using the J560 PLC Cable Set to attach to the
trailer
, connect
the alligator clips to an external power supply; otherwise, turn the trac-
tors key to the on position.
Selecting a Protocol & Registering the ECU
NEXIQ Brake-Link
uses the SAE J1587
communication
protocol to interact
with the vehicles brake controllers. It sends and receives diagnostic informa-
tion (i.e., J1587 messages) over the:
J1708 Bus
or
Power Line Carrier (PLC) (only available if the ECU(s) support En-
hanced PLC Mode; see pg .30)
If youre connecting to a tractor, use the Quick Disconnect
(Figure 2.2) to remove the alligator clips from the cable set first.
Since the tractor provides power, the alligator clips are
unnecessary and could potentially cause a short.
Figure 2.3
Power Line Carrier and J1708 Bus Illustration
Trailer ECU
J1708 Bus
Deutsch
Connector
Power Line Carrier (PLC)
Power Line ConnectorsTractor ECU
J1708 Bus
Deutsch
Connector
Vista de página 24